Acti9 RTH Timer 1C/O 8A 24-240VAC
Ideal Part Number SCHA9E16068
Manufacturer Number A9E16068
Barcode 3606480377440
Product Details
Acti9 RTH Timer 1C/O 8A 24-240VAC
This Acti9 iRTH product is a Time delay relay. The time delay range is from 0.1s to 360000s. It delays de-energizing of a load upon opening of an auxiliary contact (push button). The load is de-energized at the end of time delay T. The operating frequency is 50Hz or 60Hz. The Uc control and power supply voltage is from 24VAC to 240VAC +/-10% and 24VDC +/-10%. The single time delay cycle starts only upon release of an auxiliary contact (push button). The precision of the device is +/- 10% of the full scale. The minimum duration of control impulse is 100ms. The maximum resetting time per voltage interruption is 100ms. The nominal switching current is 21A at 250VAC. The mechanical endurance under AC1 category is over 5 x 10exp6 switchning operations. The electrical endurance under AC1 category is over 10exp5 switchning operations. The type of excitation is analog (ou analogue) with single function. The device is flashing during time delay. It includes a changeover contact. The width in 9mm pitches is 2. The degree of protection is IP20. The dimensions are (W) 18mm x (H) 93mm x (D) 72mm. The weight is 65g. The operating temperature is -5°C to + 55°C. The storage temperature is -40°C to + 70°C.
This Acti9 iRTH product is a Time delay relay. The time delay range is from 0.1s to 360000s. It delays de-energizing of a load upon opening of an auxiliary contact (push button). The load is de-energized at the end of time delay T. The operating frequency is 50Hz or 60Hz. The Uc control and power supply voltage is from 24VAC to 240VAC +/-10% and 24VDC +/-10%. The single time delay cycle starts only upon release of an auxiliary contact (push button). The precision of the device is +/- 10% of the full scale. The minimum duration of control impulse is 100ms. The maximum resetting time per voltage interruption is 100ms. The nominal switching current is 21A at 250VAC. The mechanical endurance under AC1 category is over 5 x 10exp6 switchning operations. The electrical endurance under AC1 category is over 10exp5 switchning operations. The type of excitation is analog (ou analogue) with single function. The device is flashing during time delay. It includes a changeover contact. The width in 9mm pitches is 2. The degree of protection is IP20. The dimensions are (W) 18mm x (H) 93mm x (D) 72mm. The weight is 65g. The operating temperature is -5°C to + 55°C. The storage temperature is -40°C to + 70°C.
To view pricing, availability and special offers, click the button below and login.
Login Or Register to view pricing and availabilityClick and Collect: Pick up from your branch in 1 hour