Skip to content

Acti9 RCCB 2P 40A 30mA 10kA RCD SI

Ideal Part Number SCHA9R91240 Manufacturer Number A9R91240 Barcode 3606480090486

Product Details

Acti9 iID - RCCB - 2P - 40A - 30mA - type A-SI

This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, A-SI type protection class and a 30mA earth leakage sensitivity. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C.
Request a quote for this product

Enter details to request a quote

Technical Documents

Technical Specifications

Mounting method
DIN rail
Built-in depth
44
Rated current
40
Rated voltage
230
Number of poles
2
Rated fault current
0
Leakage current type
Other
Selective protection
yes
Surge current capacity
3
Width in number of modular spacings
2
Short-time delayed tripping
no
Frequency
50/60 Hz
Degree of protection (IP)
IP20
Additional equipment possible
no
Built-in depth (unit)
mm
Rated current (unit)
A
Rated voltage (unit)
V
Rated fault current (unit)
A
Surge current capacity (unit)
kA

Branch Stock Availability

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare