Skip to content

Acti9 Impulse Relay ITLI 16A 1N/O 1N/C 24VAC 50-60Hz 12V

Ideal Part Number SCHA9C30115 Manufacturer Number A9C30115 Barcode 3606480092008

Product Details

impulse relay iTLI - 2P - 1NO+1NC - 16A - coil 12 VDC - 24 VAC 50/60Hz

This Acti9 iTLi is a modular impulse relay. It is a changeover contact with 1 normally open and 1 normally close contact. Rated current is 16A, 24VAC to 250VAC operating voltage and it operates with 24VAC or 12VDC control voltage. Electrical endurance goes up to 200000 cycles for AC-21 or 100000 cycles for AC-22. The switching frequency is 5 switching operations/minute or 100 switching operations/day. The duration of the command order should be between 50ms to 1s. It is mainly used for lighting control applications. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 18mm x (H) 84mm x (D) 60mm. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -20°C to 50°C. The storage temperature is from -40°C to 70°C. This product is compliant with IEC/EN 60669-1 and IEC/EN 60669-2-2 standard.
Request a quote for this product

Enter details to request a quote

Technical Documents

Technical Specifications

Mounting method
DIN rail
Function
Mechanical switch
Built-in depth
43
Width in number of modular spacings
1
Control voltage 1
24
Control voltage 2
12
Type of control voltage 1
AC
Type of control voltage 2
DC
Frequency control voltage 1
50
Voltage type (supply voltage)
AC
Supply voltage
24
Max. switching current (cos phi = 0.6)
16
Max. incandescent lamp load
1600
Max. load fluorescent lamp
1300
Max. load fluorescent lamp (Duo circuit)
2000
Max. load fluorescent lamp (parallel compensated)
900
Rated switch current
16
Built-in depth (unit)
mm
Control voltage 1 (unit)
V
Control voltage 2 (unit)
V
Frequency control voltage 1 (unit)
Hz
Supply voltage (unit)
V
Max. switching current (cos phi = 0.6) (unit)
A
Max. incandescent lamp load (unit)
W
Max. load fluorescent lamp (unit)
VA
Max. load fluorescent lamp (Duo circuit) (unit)
VA
Max. load fluorescent lamp (parallel compensated) (unit)
VA
Rated switch current (unit)
A

Branch Stock Availability

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare